Powerful products from BBC Cellpack Smart Energy for the grid of tomorrow
As a manufacturer and service provider for sustainable solutions in network levels 5 to 7, we know the requirements and needs for corresponding products from many years of experience.
With SGIM by BBC Cellpack Power Systems, low-voltage grids can be visualized in an instant and aligned to future requirements.
Easy: The state of the low-voltage grid can be visualised quickly, easily and cost-effectively - current data already from the very first day!
Reliable: Regardless of costly infrastructure due to web-based solution - implemented with proven industrial technology and certified according to the most recent standards, including cyber security.
Persuasive: A comprehensive package with low investment costs and operating costs. A system that adapts to the development of the smart grid and grows with the needs of customers.
Key arguments for SGIM
All-in-one solution with tried and tested hardware, transmission, visualisation and data management can monitor up to 10 low-voltage connections per unit, both 3-phase and 4-phase. Voltage, current, mains frequency, and phase angles are measured as a standard feature. Furthermore, expandable additional functions can be added using various interfaces. The measured data is automatically transferred to a portal server with archiving function and can thus be easily evaluated. Moreover, the SGIM solution is compatible with several well-known network analysis systems and asset management applications. The unit can be easily installed on a 185 mm busbar system or retrofitted without interruption. The investment and operating costs are low and the scalability of the system ensures investment protection.
Highlights
-
All-in-one solution with tried and tested hardware, transmission, visualisation, and data management
-
If required, 3-phase and 4-phase monitoring of up to 10 low-voltage connections per unit is available
-
Voltage, current, mains frequency and phase angles as an integrated standard feature, and extensible
-
easy availability of measured data on portal server with archiving function
-
Interruption-free, simple (post-)installation on 185 mm busbar systems
-
low investment and operating costs
-
Scalable
Technical data
Dimensions
-
Design: Format of a low and high-voltage switchgear combination for 185 mm busbar system
Power supply
-
Input voltage: 1 x 230 V (L1), (100 to 240 V), 50 Hz
-
Power consumption: <25 VA
Voltage measurement
-
Measurement category: IV
-
Measuring method: Lx -N
-
Resolution: 0.01 V
-
Measurement range: 1.5 x Vrated (max. 300 V)
-
Accuracy: Class 0.5
-
Measurement functions: Average value, minimum, maximum
-
Minimum averaging time: 60 s
Measurement of current
-
Measuring method: with SGIM-Rogowski sensor set (RC) or current transformer (CT) 3 or 4-wire
-
Resolution: 0.01 A (depending on RC or CT)
-
Secondary rated current: 1A
-
Measurement range: 1.7 x Irated (up to 15 kA)
-
Accuracy: Class 0.5 + accuracy RC or CT, class 1.0 with SGIM-Rogowski sensor set
-
Measurement functions: Average value, minimum, maximum
-
Minimum averaging time: 60 s
Mains frequency measurement
-
Resolution 0.01 Hz
-
Measurement functions: Average value, minimum, maximum
-
Minimum averaging time: 60 s
Power measurement
-
Measurand Apparent, active, and reactive power
-
Measurement functions: Average value, minimum, maximum
-
Minimum averaging time: 60 s for active power, 900 s for apparent and reactive power
Energy measurement (electrical work), consumption and feed
-
Measurand Apparent, active, and reactive power
-
Measurement functions: Average value, minimum, maximum
-
Minimum averaging time: 60 s for active power, 900 s for apparent and reactive power
Power quality measurement
-
Measurand THD voltage, THD current
-
Measurement functions: Average value, minimum, maximum
-
Minimum averaging time: 900 s
Additional functions (supply for external additional devices)
-
Voltage: +12 V or +24 V
-
Max. Output: 5 W
-
Sensors: Temperature and humidity
Connectivity via various modules
-
I/O module - 2 relay contacts (G5SB): Operating voltage 250 VAC, CAT II, max. operating current 3 A, 8 x digital input (0 to 12 V, 5 mA), debounce time 10 ms
-
Internet gateway: LAN, WLAN, LWL, UMTS, PLC
-
Communication: Bluetooth, Modbus, RS485
Standards:
-
Conformities: EMC Directive 2014/30/EU (4 kV / 8 kV), Low Voltage Directive 2014/35/EU, RED 2014/53/EU, RoHS 2 Directive 2011/65/EU
-
Measurement technology and communication: EN 61557-12 (P, Q, S, E, U, I, f, RMS), IEC 60870-5-104 or IEC 61850, IEC 61000, EN 61326, EN 61010